Refrigerant Pressure Sensor / Switch: Service and Repair

A/C Refrigerant Pressure Sensor Removal and Installation

Removal

1. Recover refrigerant from the A/C system with the recovery and recycling equipment referring to "Recovery" in Operation Procedure for Charging

A/C with Refrigerant.

2. Disconnect negative (-) cable from battery.
3. Disconnect A/C refrigerant pressure sensor connector.

4. Remove A/C refrigerant pressure sensor (1) from liquid pipe (2).

Installation

Reference: A/C Refrigerant Pressure Sensor and Its Circuit Inspection

Reverse removal procedure noting the following instructions.

-

Apply compressor oil to O-ring of A/C refrigerant pressure sensor.

-

Tighten A/C refrigerant pressure sensor (1) to specified torque.

Tightening torque
A/C refrigerant pressure sensor a: 11 Nm (1.1 kg-m, 8.0 lb-ft)

-

Evacuate and charge the A/C system referring to "Evacuation" and "Charge" in Operation Procedure for Charging A/C with Refrigerant.