background image

EVAP Leak Detection Pump Check

1. Check EVAP leak detection pump in EVAP leak check module as follows.

a. Connect a spherical plastic bag (1) with approximately 12.5 cm (4.92 in.) diameter (volume: 1L) to EVAP leak check module using a rubber

band (2) as shown in figure.

b. Operate EVAP canister vent valve and EVAP leak detection pump by connecting 12 V battery to EVAP leak check module terminals as shown

in figure.

c. Check that air in plastic bag is fully evacuated by EVAP leak detection pump within approximately 2 minutes. If check result is not as

described above, replace EVAP leak check module.

CAUTION:  Make sure that connection is made between correct terminals. Wrong connection can cause damage to EVAP canister
vent valve and EVAP leak detection pump in EVAP leak check module.

Leak Detector, Evaporative System|Locations|Page 2738 > < Leak Detector, Evaporative System|Locations|Page 2736