suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Electrical Specifications|Page 4577 > < Electrical Specifications|Page 4575
Page 1
background image

Alternator: Testing and Inspection

Generator Test

Slow engine cranking or low specific gravity of battery electrolyte may result from an undercharged battery due to failure in the generator even if the
charging indicator light is operating normally.

Before beginning generator test in this case, perform the following procedures.

-

Make sure that undercharged condition has not been caused by accessories being left on for extended period of time.

-

Check drive belt for proper tension.

-

If battery defect is suspected, refer to Battery Description.

-

Inspect wiring for defects. Check all connections for tightness and cleanliness, including battery cable connections at battery, starting motor leads
and ignition ground cable.

No-Load Check

NOTE:  Use fully charged battery.

1. Check for DTC.

-

N32A

-

J24B

If there is any DTC, perform trouble shooting for applicable DTC and then clear DTC.

Trouble shooting:
-

N32A

-

J24B

DTC clearance:
-

N32A

-

J24B

2. Turn off all electrical loads (5).
3. Connect voltmeter (3) and ammeter (2) as shown in figure.
4. Start engine and warm it up to normal operating temperature.

5. Run engine around 2,000 rpm and read meters.

-

If voltage is higher than standard value, check ground circuit of brushes.
If brushes are not grounded, replace IC regulator.

-

If voltage is lower than standard value, inspect rotor, stator, rectifier, bushes and regulator.

Electrical Specifications|Page 4577 > < Electrical Specifications|Page 4575