Inspecting and Testing Grand Vitara Blower Motor Relay in HVAC Module
Blower Motor Relay: Service and Repair
Heater Blower Relay
Removal
1. Disconnect negative (-) cable at battery.
2. Disable air bag system, if equipped. Refer to "Disabling Air Bag System:".
3. Open glove box, then remove screw.
4. Remove glove box.
5. Disconnect relay coupler.
6. Remove heater blower relay (1) by loosening its fastening screw (2).
Installation
1. Reverse removal procedure for installation.
2. Enable air bag system, if equipped. Refer to "Enabling Air Bag System:".