Kizashi AWD L4-2.4L (2010)
10. Check that rotor turns smoothly.
Generator Inspection
Generator Inspection
Rotor
1. Using ohmmeter (1), check for continuity between slip rings (2) of rotor. If there is no continuity, replace rotor.
Standard resistance between slip rings of rotor
1.7 - 2.1 Ohms