Sidekick JX 4D Hard Top 4WD L4-1.6L (1997)
NOTE: Do not rotate camshaft while gauging plastic is installed.
6. Remove housing and using scale on gaging plastic envelope, measure gauging plastic width at its widest point.
Journal Clearance:
Standard: 0.040 - 0.082 mm (0.0016 - 0.0032 inch).
Limit: 0.12 mm (0.0047 inch).
If measured camshaft journal clearance exceeds limit, measure journal (housing) bore and outside diameter of camshaft journal. Replace camshaft
or cylinder head assembly whichever the difference from specification is greater.
Camshaft Journal Bore Diameter: 28.000-28.021 mm (1.1024- 1.1031 inch).