suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Standard Bearing Selection|Page 435 > < Torque Values|Page 430
Page 1
background image

Crankshaft Main Bearing: Service and Repair
Standard Bearing Selection

Fig. 49  Installing Main Bearing Caps

Fig. 50  Measuring Main Bearing Clearance

    Two types of main bearings are available, standard and 0.0098 inch (0.25mm) undersize, and each of them has five kinds of bearings differing in
tolerance. Each main bearing cap is stamped with a number and an arrow. When installing bearing cap, arrow must point towards crankshaft pulley side, 
Fig. 49. Check main bearing clearance as follows:

1.

Clean bearings and crankshaft main journals using a suitable solvent.

2.

Place a piece of gaging plastic the full width of the bearing (parallel to crankshaft) on journal, avoiding oil passage hole.

3.

Install bearing cap and tighten cap bolts to specifications. Do not rotate crankshaft while gaging plastic is installed.

4.

Remove bearing cap. Using scale on gaging plastic envelope, measure gaging plastic width at its widest point, Fig. 50.

5.

If clearance exceeds .0023 inch, replace bearing. Always replace both upper and lower inserts as a unit. A new standard bearing may produce
proper clearance, if not, it will be necessary to regrind crankshaft journal for use of 0.0098 inch undersize bearing. After selecting
appropriate bearing, recheck clearance.

    If bearing is in malcondition, or bearing clearance is out of specification, select a new standard bearing according to the following procedure.

Fig. 51  Distinguishing Crankshaft Journal Diameters

Standard Bearing Selection|Page 435 > < Torque Values|Page 430