Swift L4-1298cc 1.3L SOHC MFI (1997)
Alternator: Service and Repair
UNIT REPAIR OVERHAUL
DISMOUNTING AND REMOUNTING
1) Disconnect negative cable at battery.
2) Disconnect "B" terminal wire and coupler from generator.
3) Remove generator drive belt adjusting bolt and loosen adjuster arm bolt.
4) Remove generator cover.
5) Remove generator mounting bolts and nut, and then remove generator.
6) To remount, reverse above procedure giving specified tension to drive belt.
Tightening Torque
(a): 18-28 N.m (1.8-2.8 kg-m, 13.5-20.0 lb-ft)
(b): 4-7 N.m (10.4-0.7 kg-m,3.0-5.0 lb-ft)
(c): 6-10 N.m (0.6-1.0 kg-m. 4.5-7.0 lb-ft)
DISASSEMBLY
1) For easier reinstallation, provide match marks on both front and rear housing as shown before separating them.