Swift GA L4-1298cc 1.3L SOHC MFI (2001)
Ignition Cable: Testing and Inspection
HIGH-TENSION CORDS
1. Disconnect high-tension cords from ignition coil assemblies while gripping each cap.
2. Pull out high-tension cords from spark plugs while gripping each cap.
CAUTION: Pull out each connection by gripping cap portion so as not to damage their inside wire (resistive conductor).
3. Measure resistance of high-tension cord by using ohmmeter.
High-tension cord resistance: 4 - 10 k ohms/m 1.2 - 3.0 k ohms/ft)
4. If resistance exceeds specification, replace high-tension cord(s).
5. Install high-tension cords.