SX4 2WD L4-2.0L (2007)
d. Install connecting rod bearing cap (1) as follows.
i. Point arrow mark (2) on cap to crankshaft pulley side.
ii. Apply engine oil to connecting rod bolts (3).
iii. Tighten all connecting rod bolts to 15 Nm (1.5 kgf-m, 11.0 ft. lbs.).
iv. Retighten them by turning through 45°.
v. Repeat step d) once again.
Tightening torque
Connecting rod bolt a: Tighten 15 Nm (1.5 kgf-m, 11.0 ft. lbs.), 45° and 45° by the specified procedure
NOTE: Do not turn crankshaft with gauging plastic installed.