a. Using bulb (3.4 W) (5) and service wire, connect battery positive terminal to "3" terminal of blower motor controller as shown figure.
b. Using service wire, connect battery negative terminal to "1" terminal of blower motor controller.
c. Arrange 3 new 1.5 V batteries (6) in series (check that total voltage is 4.5 - 5.0 V) and connect its positive terminal to "2" terminal of blower
motor controller and negative terminal to "1" terminal of blower motor controller.
Then, check that bulb lights. If bulb does not light under the above conditions, replace blower motor controller.