SX4 4WD L4-2.0L (2008)
iii. Turn ON ignition switch.
Using service wire, ground C01-13 terminal (1) circuit of special tool (valve ON: B ) and unground it (valve OFF: A).
2. Check purge valve (2) for operation and vacuum passage for clog when valve is switched ON and OFF by using SUZUKI scan tool or service
wire.
If check result is not satisfactory, check hoses, EVAP canister purge valve, wire harness and connections.