SX4 4WD L4-2.0L (2008)
16. Disconnect pipe from the outlet nozzle (1) of EVAP leak check module.
17. Plug outlet nozzle with finger or the rubber plug.
CAUTION: The ventilation nozzle of EVAP leak check module must be blocked securely. The reason for this is that the EVAP system in
its design cannot be sealed completely even though the EVAP canister vent valve and the EVAP canister purge valve are both closed
because the leak check module internally opens to atmosphere through the leak detection pump. For this reason, if the ventilation nozzle
of the leak check module is not blocked completely, smoke will leak through it possibly resulting in a diagnostic error of EVAP leak.
18. Operate EVAP canister purge valve as follows. If you have SUZUKI scan tool, perform the step a). If not, perform the step b).
a. Using SUZUKI scan tool