suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

M/T - Shift Lever Vibration In 3rd Gear|Page 3406 > < M/T - Shift Lever Vibration In 3rd Gear|Page 3404
Page 4
background image

2)

Disconnect gear shift and gear select control cables from transaxle.

3)

Remove gear shift interlock bolt (1) and 5th to reverse interlock guide bolt (2) from transaxle case.

4)

Remove gear shift & select shaft assembly (3).

Installation

1)

Clean mating surface of guide case (1) and left case (5), apply sealant to left case as shown in figure by such amount that its section is 1.5 mm
(0.059 in.) in diameter, mate guide case with left case.

"B": Sealant 99000-31260 (SUZUKI Bond No.1217G)

2)

Install guide case bolts No. 1 to which thread lock cement has been applied and guide case bolts No. 2 (2), and tighten them to specified torque.

:Sealant 99000-31260 (SUZUKI Bond No. 1217G)

Tightening torque

Guide case bolt No. 1: 23 Nm (2.3 kgf-m, 17.0 lbft)

Guide case bolt No. 2 (a): 23 Nm (2.3 kgf-m, 17.0 lb-ft)