Refrigerant Pressure Sensor / Switch: Testing and Inspection

Dual Pressure Switch

1. Check dual pressure switch (1) on liquid pipe for continuity at normal temperature (approx. 25 °C (77 °F)) when A/C system has a proper charge

of refrigerant and when A/C system (compressor) is under operation. In each of these cases, switch should show proper continuity.

2. Using a manifold gauge set, check switch for operation at specified pressure as shown, refer to "PERFORMANCE DIAGNOSIS".

Dual pressure switch specification
Switch ON : above "C" and below "D"
Switch "OFF": below "A" or above "B"
"A" : Approx. 200 kPa (2.0 kg/sq.cm)
"B" : Approx. 3200 kPa (32 kg/sq.cm)
"C" : Approx. 230 kPa (2.3 kg/sq.cm) 
"D" : Approx. 2800 kPa (28 kg/sq.cm)

Tightening torque: 
Dual pressure switch: 10 N.m (1.0 kg-m, 7.5 lb-ft)