background image

5. Check that plunger (1) of IAC valve moves once and then stops as soon as ignition switch (2) is turned OFF after cranking engine for 2 sec.

If plunger (1) of IAC valve does not operate at all, check wire harnesses for open and short. If wire harnesses are in good condition, replace IAC
valve and recheck.

NOTE:  This check should be performed by two people, one person operates ignition switch while the other checks plunger operation.