Using ohmmeter, check all leads for continuity. If there is no continuity, replace stator.

-

Using ohmmeter, check that there is no continuity between coil leads and stator core. If there is continuity, replace stator.

Brush and brush holder

Check each brush for wear by measuring its length as shown. If brush is found worn down to service limit, replace brush.

Exposed brush length "a"
Standard: 10.5 mm (0.413 in.)

Limit : 4.5 mm (0.351 in.)

Rectifier

-

Positive Rectifier
1. Using an ohmmeter, connect one tester probe to the "B" terminal and the other to each rectifier terminal.
2. Reverse the polarity of the tester probes and repeat step 1).
3. Check that one shows continuity and the other shows no continuity.

If there is continuity, replace the rectifier.

Symptom Related Diagnostic Procedures|Page 2575 > < Symptom Related Diagnostic Procedures|Page 2573