Vitara JS (2Dr) 2WD L4-1.6L DOHC MFI (1999)
![background image](/suzuki/vitara_js_(2dr)_2wd/l4-1.6l_dohc_mfi/Page-380001.png)
Valve Cover: Service and Repair
REMOVAL
1) Disconnect negative cable at battery.
2) Remove ignition coil assemblies with high-tension cord.
3) Disconnect PCV valve and breather hose from head cover.
4) Detach accelerator cable from clamp.
5) Remove cylinder head cover with cylinder head cover gasket and O-rings.
INSTALLATION
1) Install O-rings and cylinder head cover gasket to cylinder head cover.
NOTE: Be sure to check each of these parts for deterioration or any damage before installation and replace if found defective.
2) Install cylinder head cover to cylinder head and tighten cover bolts to specified torque.
Tightening Torque (a): 11 Nm (1.1 kg-m, 8.0 ft. lbs.)
NOTE: When installing cylinder head cover, use care so that cylinder head cover gasket or O-rings will not get out of place or fall off.