Vitara JX (2Dr) 4WD L4-1.6L DOHC MFI (1999)
Power Door Lock Control Module: Testing and Inspection
1. Disconnect power door lock controller coupler.
2. Connect (+) wire and (-) wire of 12 V battery to terminal "A" "E" and "F" as shown in figure.
3. Disconnect cord from terminal "E" and connect it to terminal "G".
4. Repeat Steps 2) and 3) several times and if relay operation is heard every time, it means that controller is operating.