suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Adhesive Installation of Stationary Windows (Liftgate)|Page 15936 > < Adhesive Installation of Stationary Windows (Liftgate)|Page 15934
Page 11
background image

NOTE:  Do not direct a hard stream of high pressure water to the freshly applied urethane adhesive.

29. Use a soft spray of warm water in order to immediately water test the window.
30. Inspect the window for leaks.
31. If any leaks are found, use a plastic paddle in order to apply extra urethane adhesive at the leak point.
32. Retest the window for leaks.

WARNING:  Insufficient curing of urethane adhesive may allow unrestrained occupants to be ejected from the vehicle resulting in
personal injury.
^

For the moisture-curing type of urethane adhesive, allow a minimum of 6 hours at 21°C (70°F) or greater and with at least 30 percent
relative humidity. Allow at least 24 hours for the complete curing of the urethane adhesive.

^

For the chemical-curing type of urethane adhesive, allow a minimum of 1 hour.

Do NOT physically disturb the repair area until after these minimum times have elapsed.

33. Maintain the following conditions in order to properly cure the urethane adhesive:

^

Partially lower a door window in order to prevent pressure buildups when closing doors before the urethane adhesive cures.

^

Do not drive the vehicle until the urethane adhesive is cured. Refer to the above curing times.

^

Do not use compressed air in order to dry the urethane adhesive.

34. Complete the window installation.

Adhesive Installation of Stationary Windows (Liftgate)|Page 15936 > < Adhesive Installation of Stationary Windows (Liftgate)|Page 15934