Lifter / Lash Adjuster: Procedures

Valve Lifters Cleaning and Inspection 

CAUTION:  Refer to Valve Lifter Priming Notice. 

1. Inspect the stationary hydraulic lash adjuster (SHLA) in the following areas:

^

A plugged oil passage (1)

^

A scored or worn camshaft follower pivot area (2)

^

A damaged or broken retainer (3), some applications

^

A severely scuffed or worn SHLA body (4)

2. Replace the SHLA or SHLAs as necessary.