suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Recirculation Actuator Replacement|Page 14418 > < Recirculation Actuator Replacement
Page 2
background image

CAUTION: Refer to [Fastener Notice].

2. Install the recirculation actuator screws to the HVAC module.

Tightening torque
Tighten the screws to 1.5 N.m (13 lb.in).

3. Connect the electrical connector to the recirculation actuator.
4. Cycle the ignition and verify proper operation.
5. Install the instrument panel upper trim panel. Refer to [Instrument Panel Upper Trim Panel Replacement].

Recirculation Actuator Replacement|Page 14418 > < Recirculation Actuator Replacement