Control Module HVAC: All Technical Service Bulletins
A/C - Controls Inoperative After Remote Starting

Section Title: HVAC

TSB No.: TS 08 11217

Division: Automotive

Category: Technical

SUBJECT: 
HEATING, VENTILATION, AND AIR CONDITIONING (HVAC) CONTROLS INOPERATIVE AFTER REMOTE START

MODEL(S): 
XL7 (JC636)

YEAR: 
2007-2008

CONDITION: 

HVAC controls become inoperative following the remote start event.

CAUSE: 

Internal operating software of HVAC module.

CORRECTION: 

DO NOT REPLACE THE HVAC MODULE!

Please follow the service manual procedure to reprogram the HVAC module with the latest software. Be sure to click "Clear DTC's" after programming
finishes. See below.