suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Procedures|Page 3207 > < Procedures|Page 3205
Page 10
background image

Tightening torque

Tighten the nut to 12 N.m (106 lb.in).

3. Remove the protective caps from the condenser, the evaporator outlet hose, and the TXV.
4. Install the new sealing washer to the liquid line. Refer to [Sealing Washer Replacement].
5. Route the condenser end of the liquid line into position.
6. Install the liquid line to the condenser.

NOTE:  Use a large pair of pliers to hold the fitting while tightening the nut. Be careful not to twist the line.