suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Inflator Module Handling and Scrapping|Page 14836 > < Inflator Module Handling and Scrapping|Page 14834
Page 6
background image

NOTE:  On a dual stage inflator module, both connectors must be attached to the deployment harness adapter. This will ensure that both stage 1
and stage 2 of the deployment loops are energized, regardless of the deployment state.

15. Connect the inflator module (1) to the adapter (2) on the SIR deployment harness (3).

NOTE:
^

The rapid expansion of gas involved with deploying an inflator module is very loud. Notify all the people in the immediate area that you intend
to deploy the inflator module.

^

When the inflator module deploys, the deployment fixture may jump about 30 cm (1 ft) vertically. This is a normal reaction of the inflator
module due to the force of the rapid expansion of gas inside the inflator module.

^

If you are deploying a dual stage inflator module with stage 1 already deployed, the fixture may not move and the noise may have been
reduced.

16. Clear the area of people.

Inflator Module Handling and Scrapping|Page 14836 > < Inflator Module Handling and Scrapping|Page 14834