suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Refrigerant Control Solenoid Valve|Testing and Inspection|Page 3441 > < Refrigerant|Capacity Specifications|Page 3437
Page 1
background image

Refrigerant Control Solenoid Valve: Testing and Inspection

A/C Solenoid Valve

1. Connect special tool to solenoid valve (1).

Special tool
a. : 0991747910

2. Check that solenoid valve is closed when vacuum is applied to solenoid valve.

If solenoid valve is opened, replace solenoid valve.

3. Check that solenoid valve (1) is opened when connect battery to solenoid valve as shown in the figure.

NOTE:  Solenoid valve terminal is no polarity.

Refrigerant Control Solenoid Valve|Testing and Inspection|Page 3441 > < Refrigerant|Capacity Specifications|Page 3437