Field Remedy: 2275
Subject: |
Electric windows - Malfunction |
Models: |
Engines: |
Option: |
All |
All |
Only electric windows with protective
system |
Complaint: |
I. Automatic opening and closing function of
the windows not possible (power supply was cut off). II. Windows
open above the middle position. |
Cause: |
I. Window electronic not activated. II.
Window encounters resistance (e.g. ice). |
Production: |
|
Remedy:
Note:
Before changing any parts follow the instruction below.
In case of customer complaint I:
- Close doors, ignition on.
- Close window completely and hold 'close'- button for 5 seconds.
Note for Antara only:
Do NOT!! fully pull the button into end position,
hold it for 5 seconds in half way position.
- Open window completely do not interrupt.
- Repeat for each window.
In case of customer complaint II:
- Try to close window 3 times, next closing attempt
the window should close.
- If not, close the window in stages by intermittent
pressing the button and hold 'close'- button for further 5 seconds.
Note for Antara only:
Do NOT!! fully pull the button into end position,
hold it for 5 seconds in half way position.
- If efforts were unsuccessful interrupt power supply
(pull window lifter fuse for a second) and repeat the procedure.
FunctionalGroup: |
C - Equipment/Windows |
Complaint Group: |
04 - Electrical failures,13 - No/Poor
Function |
Trouble Code: |
None |
|