Remove
Disconnect wiring harness plug for mixture regulation oxygen
sensor (3).
Detach mixture regulation oxygen sensor from exhaust manifold
with KM-6179 (2).
Caution
When re-using mixture regulation oxygen sensor, coat thread (1)
of mixture regulation oxygen sensor with special grease
(black).
Install
Install mixture regulation oxygen sensor in exhaust manifold
– tightening torque 30 Nm / 22.5 lbf. ft.
Connect wiring harness plug for mixture regulation oxygen
sensor.
|