vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Heater Outlet Hose Replacement - 2.0L Diesel LBS > < Compressor Pressure Relief Valve Replacement - 1.6L LLU

Heater Outlet Hose Replacement (1.4L LUJ and LDD)

Removal Procedure

1. Remove the plenum water deflector. Refer to Plenum Water Deflector Replacement - Center .

           2189376


2. Remove the 2 heater outlet hose clamps (1).
3. Remove the heater outlet hose (2).

           2189377


4. Remove the heater outlet hose clamp (2).
5. Remove the heater outlet hose (3) from the radiator surge tank (1).

Installation Procedure


           2189377


1. Install the heater outlet hose (3) to the radiator surge tank (1).
2. Install the heater outlet hose clamp (2).

           2189376


3. Install the heater outlet hose (2).
4. Install the 2 heater outlet hose clamps (1).
5. Install the plenum water deflector. Refer to Plenum Water Deflector Replacement - Center .
6. Drain the cooling system. Refer to Cooling System Draining and Filling .

Heater Outlet Hose Replacement - 2.0L Diesel LBS > < Compressor Pressure Relief Valve Replacement - 1.6L LLU