Workshop Manuals Factory service & repair Vauxhall
01 Preface02 General Information03 Body Hardware and Trim04 Body Repair05 Body Systems06 General Vehicle Information07 Brakes08 Diagnostic Navigation09 Driveline/Axle10 Driver Information and Entertainment11 Engine12 HVAC13 Power and Signal Distribution14 Roof15 Safety and Security16 Seats17 Steering18 Suspension19 Transmission/Transaxle
Vauxhall Astra J12 · HVAC
12 · Heating & A/C

Actuator Recalibration

Make
Vauxhall
Model
Astra J
Section
Diagnostic Information and Procedures › Miscellaneous › Actuator Recalibration
HVACActuator Recalibration

Actuator Recalibration

When replacing the HVAC control module it will be necessary to allow the HVAC control module to perform a calibration process. When installing the HVAC control module be sure to perform the following:


Note: 
Do not adjust any controls on the HVAC control module while the HVAC control module is self-calibrating. If interrupted, improper HVAC performance will result.

1. Place the ignition switch to the OFF position.
2. Disconnect the scan tool.
3. Install the HVAC control module.
4. Connect all previously disconnected components.
5. Ignition ON
6. Wait 40 s for the HVAC control module to self-calibrate.
7. Verify that no DTCs have set as current DTCs.

When replacing the HVAC actuator it will be necessary to allow the HVAC control module to perform a calibration process. When installing the HVAC actuator be sure to perform one of the following:

Preferred Method - with Scan Tool


Note:  Do not adjust any controls on the HVAC control module while the HVAC control module is self-calibrating. If interrupted, improper HVAC performance will result.
1. Clear all DTCs.
2. Place the ignition switch in the OFF position.
3. Install the HVAC actuator.
4. Connect all previously disconnected components.
5. Start the vehicle.
6. With the scan tool, initiate the HVAC Actuators Learn feature of the Remote Heater and Air Conditioning Control Module Configuration/Reset Functions menu.
7. Verify that no DTCs have set as current DTCs.

Alternate Method - without Scan Tool


Note:  Do not adjust any controls on the HVAC control module while the HVAC control module is self-calibrating. If interrupted, improper HVAC performance will result.
1. Clear all DTCs.
2. Place the ignition switch to the OFF position.
3. Install the HVAC actuator.
4. Connect all previously disconnected components.
5. Remove the HVAC control module fuse for a minimum of 10 s.
6. Install the HVAC control module fuse.
7. Ignition ON
8. Wait 40 s for the HVAC control module to self-calibrate.
9. Verify that no DTCs have set as current DTCs.

Parts & tools for this job For Vauxhall Astra