Air Temperature Malfunction

Diagnostic Instructions

•  Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
•  Review Strategy Based Diagnosis for an overview of the diagnostic approach.
•  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

Diagnostic Fault Information



Circuit


Short to Ground


Open/High Resistance


Short to Voltage


Signal Performance


Stepper Motors 12V Reference


B023A 02, B0223 06, B0233 06, B0418 06


B0223 06, B0233 06, B0418 06


-


-


Air Temperature Actuator Control 1


B0418 06


B0418 06


B0418 01


1


Air Temperature Actuator Control 2


B0418 06


B0418 06


B0418 01


1


Air Temperature Actuator Control 3


B0418 06


B0418 06


B0418 01


1


Air Temperature Actuator Control 4


B0418 06


B0418 06


B0418 01


1


1. Air Temperature Malfunction

 

Circuit/System Description

With the temperature switch at the HVAC control, the desired air temperature flap position can be put in. The selected value is sent to the HVAC control module via the LIN-Bus. The HVAC control module supplies a 12 V reference voltage to the stepper motor and energizes the 4 stepper motor coils with a pulsed ground signal. The stepper motor moves the temperature flap into the calculated position, in order to reach the selected temperature.

Diagnostic Aids

Check the following mechanical fault sources:

•  Air distribution box
•  Air distribution hoses/air distribution ducts

Reference Information


Schematic Reference

HVAC Schematics


Connector End View Reference

Component Connector End Views


Description and Operation

Manual HVAC Description and Operation


Electrical Information Reference


Scan Tool Reference

Control Module References for scan tool information

Circuit/System Verification

1. Measure actual evaporator temperature using a thermometer. Compare this value to the scan tool A/C Evaporator Temperature Sensor parameter. The measured temperature should be within 5°C (9°F) difference of parameter value.
    ⇒  If not within the specified range

Refer to DTC B3933 .     ⇓  If within the specified range

2. Engine is running, activate and deactivate the A/C switch. Verify the A/C compressor can be activated and deactivated.
    ⇒  If the A/C compressor cannot be activated or deactivated

Refer to Air Conditioning Compressor Malfunction .     ⇓  If the A/C compressor can be activated or deactivated

3. Verify the engine reaches its operating temperature.

Circuit/System Testing

1. Ignition ON, turn the temperature knob in all positions. Verify the scan tool Left Temperature Knob Position parameter. The reading should correspond to the selected temperature.
    ⇒  If not the specified value

Replace the A26 HVAC Controls.     ⇓  If the specified value

2. Replace the M6 Air Temperature Door Actuator and verify the M6 Air Temperature Door Actuator can be put into all positions.
    ⇒  If the M6 Air Temperature Door Actuator cannot be put into all positions

Replace the K33 HVAC Control Module.     ⇓  If the M6 Air Temperature Door Actuator can be put into all positions

3. All OK.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.