Power Outlet Receptacle Malfunction
Diagnostic Instructions
Diagnostic Fault Information
Circuit
|
Short to Ground
|
Open/High Resistance
|
Short to Voltage
|
Signal Performance
|
Relay Coil Ignition
|
1
|
1
|
2
|
--
|
Relay Coil Ground
|
--
|
1
|
--
|
--
|
Relay Switch B+
|
1
|
1
|
--
|
--
|
Relay Switch Control
|
1
|
1
|
2
|
--
|
Ground
|
--
|
1
|
--
|
--
|
1. Power Outlet Receptacle or Cigarette Lighter Malfunction
2. Power Outlet Receptacle or Cigarette Lighter Always ON
|
Circuit/System Description
The 12 V DC accessory power receptacle and cigarette
lighter are supplied B+ when the ignition is on or in the accessory
position.
Reference Information
Schematic Reference
Cigar Lighter/Power Outlet Schematics
Connector End View Reference
Component Connector End Views
Description and Operation
Power Outlets Description and Operation
Electrical Information Reference
Circuit/System Verification
Install a 12 V DC accessory into a X80 accessory power
receptacle or activate the cigarette lighter. Ignition ON, command
the Auxiliary Power Relay Command ON and OFF with a scan tool. The
KR70 auxiliary power relay should click and the 12 V DC
accessory or the E32 cigarette lighter should have power.
Circuit/System Testing
Accessory Power Receptacle or Cigarette Lighter
Malfunction
- Ignition OFF, disconnect the KR70 auxiliary power
relay.
- Test for less than 10 Ω between the ground
circuit terminal 86 and ground.
⇒ |
If greater than the specified range, test the
ground circuit for an open/high resistance. |
- Verify that a test lamp does not illuminate between
the control circuit terminal 30 and ground.
⇒ |
If the test lamp illuminates, test the control
circuit for a short to voltage. |
- Ignition ON, verify that a test lamp illuminates
between the ignition circuit terminal 85 and ground.
⇒ |
If the test lamp does not illuminate, test the
ignition circuit for a short to ground or an open/high
resistance. |
- Verify that a test lamp illuminates between the B+
circuit terminal 87 and ground.
⇒ |
If the test lamp does not illuminate, test the B+
circuit for a short to ground or an open/high resistance. If the
circuit tests normal and the B+ circuit fuse is open, test the
control circuit terminal 30 for a short to ground. |
- Disconnect the harness connector at the inoperative
X80 accessory power receptacle or E32 cigarette lighter.
- Test for less than 10 Ω between the ground
circuit terminal C and ground.
⇒ |
If greater than the specified range, test the
ground circuit for an open/high resistance. |
- Connect the harness connector at the X80 accessory
power receptacle.
- Connect a 20 A fused jumper wire between the KR70
auxiliary power relay B+ circuit terminal 87 and the control
circuit terminal 30. Verify the accessory has power.
⇒ |
If the accessory does not have power, test the
control circuit for a short to ground or an open/high resistance.
If the circuit tests normal, test or replace the appropriate X80
accessory power receptacle or E32 cigarette lighter. |
- If all circuits test normal, test or replace the KR70
auxiliary power.
Cigarette Lighter LED Malfunction
- Disconnect the harness connector at the E32 cigarette
lighter.
- Test for less than 10 Ω between the ground
circuit terminal C and ground.
⇒ |
If greater than the specified range, test the
ground circuit for an open/high resistance. |
- Ignition ON, interior lights dimmer switch on high,
verify that a test lamp illuminates between the control circuit
terminal B and ground.
⇒ |
If the test lamp does not illuminate, test the
control circuit for a short to ground or an open/high
resistance. |
- If all circuits test normal, replace the E32 cigarette
lighter.
Component Testing
Relay Test
- Ignition OFF, disconnect the KR70 auxiliary
power.
- Test for 60-180 Ω between terminals 85
and 86.
⇒ |
If not within the specified range, replace the
relay. |
- Test for infinite resistance between the following
terminals:
⇒ |
If not the specified value, replace the
relay. |
- Install a 20 A fused jumper wire between relay
terminal 85 and 12 V. Install a jumper wire between relay
terminal 86 and ground. Test for less than 2 Ω between
terminals 30 and 87.
⇒ |
If greater than specified range, replace the
relay. |
Repair Instructions
Perform the
Diagnostic Repair Verification after completing the diagnostic
procedure.
|