vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Flat Wire Repairs > < Testing for Short to Ground

Testing for a Short to Voltage

Special Tools

EL-39200  Digital Multimeter (DMM)

For equivalent regional tools, refer to Special Tools .

Caution: Refer to Test Probe Caution .

The following procedure tests for a short to voltage in a circuit.

1. Remove the power feed (i.e. fuse, control module) from the suspect circuit.
2. Disconnect the load.
3. Set the Digital Multimeter (DMM) to the V (DC) position.
4. Connect the positive lead of the DMM to one end of the circuit to be tested.
5. Connect the negative lead of the DMM to a good ground.
6. Turn ON the ignition and operate all accessories.
7. If the voltage measured is greater than 1 V, there is a short to voltage in the circuit.

Flat Wire Repairs > < Testing for Short to Ground