vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

TECHNICAL DATA - Ignition Coll for Electronically Controlled Ignition System > < TECHNICAL DATA IGNITION DISTRIBUTOR - Identification Data

Ignition Distributor

 

Adjusting Data

 

Manufacturer                                                          Delco-Remy

 

Code number                                            1 103 478            1 103 623          1 103 628          1 111 398

 

Ignition timing adjustment                         Adjustment is made at idle speed. Ignition markings must align.

 

Ignition timing adj. in °CA/rpm                 0 to 1/1000          0 to 1/1000        0 to 1/1000        1 to 1/1000

                                                                  9 to 15/180          9 to 14/1800      9 to 14/1800      5 to 10/1600

                                                                  26 to 30/4200      18 to 22/4200    18 to 22/4200    22 to 26/4200

 

Final adjustm.    °CA.                          26 to 30               18 to 22             18 to 22             22 to 26

 

Ignition timing adjustment with vacuum

Start                          at kPa                        12 to 17               10 to 14             12 to 17             12 to 17

Finish                       at kPa                        124,5 to 26          22 to 24             19 to 20             22 to 26

       Final adjustm..   °CA.                          12,5 to 16,5         12,5 to 16,5       6 to 10               12,5 to 16,5

 

Dwell angle             °                                              electronic dwell angle control

Closure time             %                                                                   --

 

Condensor capacity  µF                                                                 --

 

Resistance of

ignition lead             ohms                                         approx. 20 000 (maximum)

 

When close interference

resistance of rotor     ohms                                                    5000 +  20%

 

Resistance of

cable "4"                   ohms                                                             --

 

Ignition Distributor

 

 

Manufacturer

Delco

Bosch

Code number

3 470 271

0 231 170 339

0 237 021 021

0 237 021 025

Ignition timing adjustment

Adjustment is made at idle speed. Ignition markings must align.

Ignition adjustment in

°CA rpm

 

 

 

Final adjustment     °CA rpm

 

0 to 1/1000

1 to 8/1500

12 to 17/2500

15 to 20/3000

20 to 24/3800

20 to 24

0 to 4/1200

7 to 12/1600

18 to 22/3000

 

 

18 to 22

0 to 1/1000

3 to 12/1400

11 to 15,5/2000

16,5 to 20,5/3000

16 to 20/4000

16,5 to 20,5/3000

15,5 to 19,5/6000

Ignition adjustment with vacuum

Start

at kPa

at mbar

Finish

at kPa

at mbar

Final adjustment     °CA rpm

 

 

 

13 to 17

 

 

24,5 to 25,5

 

12,5 to 16,5

 

 

 

 

120 to 170

 

 

250 to 260

6 to 10

 

 

 

 

120 to 195

 

 

330 to 350

13 to 15

Dwell angle                           °

Closure time                           %

47 to 53 at min. 0,4 mm

53 to 59 Electrode gap

electronic dwell angle control

-

Condensor capacity                mF

0,17 to 0,23

-

Resistance of ignition lead     ohms

approx. 20 000 (maximum)

When close interference resistance of rotor                                   ohms

5000 + 20%

1000

Resistance of cable "4"          ohms

-

approx. 10 000

(maximum)

5000 to 8000

 

 

Ignition Distributor

 

Adjusting Data

 

 

Manufacturer

Bosch

Code number

0 237 021 023

0 237 503 001

Ignition timing adjustment

Adjustment is made at idle speed.

Ignition markings must align.

Ignition adjustment in

°CA rpm

 

 

 

Final adjustment     °CA rpm

 

0 to 3/1400

13 to 17/3200

23 to 25/5000

 

 

23 to 25

 

 

 

Electronically controlled.

Ignition adjustment with vacuum

 

Start

at kPa

at mbar

Finish

at kPa

at mbar

Final adjustm.         °CA rpm

 

 

 

 

120 to 170

 

 

250 to 260

11,5 to 16,5

 

 

 

 

80 to 140

 

 

280 to 320

11,5 to 15,5

Dwell angle

Closure time                           %

-

Condensor capacity                mF

-

Resistance of ignition lead     ohms

approx. 20 000 (maximum)

When close interference resistance of rotor                                        ohms

1000

Resistance of cable "4"          ohms

5000 - 8000

 

 

 

Ignition Distributor

 

Adjusting Data

 

 

Manufacturer

Bosch

Code number

0 237 504 002

0 237 504 005

0 237 504 005

Ignition timing adjustment

Adjustment is made at idle speed.

Ignition markings must align.

Ignition adjustment in

°CA rpm

 

Final adjustment     °CA rpm

 

 

 

Electronically controlled.

Ignition adjustment with vacuum

 

Start       at kPa

 

Finish     at kPa

 

 

 

12 to 16 (advance)

20 to 30 (retard)

18 to 20 (advance)

30 to 32 (retard)

Final adjustment     °CA rpm

6 to 10 (advance)

3 to 7 (retard)

12 to 16 (advance)

3 to 7 (retard)

Dwell angle

Closure time                           %

-

Condensor capacity                mF

-

Resistance of ignition lead     ohms

approx. 20 000 (maximum)

When close interference resistance of rotor                                        ohms

1000

Resistance of cable "4"          ohms

-

 

 

TECHNICAL DATA - Ignition Coll for Electronically Controlled Ignition System > < TECHNICAL DATA IGNITION DISTRIBUTOR - Identification Data