vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Adjustment data for Corsa-D Z 14 XEP LPG (1.4 LPG ecoFlex) 66 kW > < Adjustment data for Corsa-D Z 12 XEP LPG (1.2 LPG ecoFlex) 59 kW

Adjustment data for Corsa-D A 14 XEL (1.4 TWINPORT ecoFLEX) 64 kW

Corsa-D A 14 XEL (1.4 TWINPORT ecoFLEX) 64 kW

1

Vehicle manufacturer field no 2

 

Opel

2

Vehicle manufacturer code no 2

[HSN]

0035

3

Type and version field no 3

 

S - D

4

Type and version code no 3

[TSN]

ALK

5.1

Engine code / model series / model year

 

L2Z / DOHC / 2011 -

5.2

CLCC / EGR / knock control

[yes/no]

yes/no/yes

5.3

Manufacturer (mixture system)

 

 

5.4

Fuel system

 

Fuel injection

5.5

Designation (engine management)

 

GM SO (E83)

5.6

Ignition system type

 

Direct ignition

5.7

Number of cylinders / arrangement of cylinders

 

4 / in-line

5.8

Capacity

[cm 3 ]

1398

5.9

Output

[kW/rpm]

64 / 6000

5.10

Max. torque

[Nm/rpm]

130 / 4000

5.11

Compression ratio

 

10.5 : 1

5.12

Bore x stroke

[mm] x [mm]

73.4 x 80.6

5.13

Trailer load, braked

[kg]

1000

5.14

Trailer load, not braked

[kg]

500

5.15

Octane number requirement, recommended / alternative

[RON (MON)]

95 1) (85) / 98 1)   2) (88), 91 3) (82.5)

5.16

Tax class / emissions class (D)

 

EURO 5

5.17

Code No.

[SN]

35A0

6

Installation location diagnostic point

 

Centre console, above ashtray

7

Conditioning time [sec]

min.

30

8

Conditioning speed

[rpm]

3000

9

Engine temperature min

[°C]

60

10.1

Idle speed, MT (min/max)

[rpm]

670 - 830

10.2

Idle speed, AT, position "P" (min/max)

[rpm]

 

11

Increased idle speed (min/max)

[rpm]

2800 - 3200

12

CO increased idle speed

[% vol]

0.2

13

Lambda increased idle speed (min/max)

 

0.97 - 1.03

14

Test speed (min/max), control sensor signal

[rpm]

670 - 830

15

Spring sensor(s) or wide band sensor(s)

 

S

16

Min. voltage increase

[mV]

300

17.1

Lambda value control sensor(s)

   

17.2

Control sensor(s) amperage

[mA]

 

17.3

Voltage control sensor(s)

[V]

 

Nos 7 + 8 are optional fields

Nos 17.1-17.3 apply for wide band sensors only



1 ) Knock control adjusts ignition automatically depending on the type of fuel in the tank (octane number).
2 ) No power / torque advantages with RON 98.
3 ) If 91 RON is used there will be slight losses of power and torque.

Adjustment data for Corsa-D Z 14 XEP LPG (1.4 LPG ecoFlex) 66 kW > < Adjustment data for Corsa-D Z 12 XEP LPG (1.2 LPG ecoFlex) 59 kW