Replace air cleaner housing
Remove
1. |
Remove air cleaner housing
• |
Disconnect hot film mass air flow meter wiring harness plug
(1)
|
• |
Detach engine vent hose from air intake pipe
|
• |
Detach air intake pipe from throttle valve module
|
• |
Pull air intake pipe (4) from air cleaner housing
|
• |
Press air cleaner housing from rubber bearings
– |
Push air cleaner housing upward (arrow)
|
– |
Push air cleaner housing inward (arrow)
|
|
|
|
|
2. |
Remove attaching parts
Note: The stages below
are only to be undertaken when replacing the air cleaner
housing.
• |
Detach upper part of air cleaner housing
|
• |
Take out air filter insert
|
|
Install
3. |
Fit attaching parts
Note: The stages below
are only to be undertaken when replacing the air cleaner
housing.
• |
Place air cleaner insert in lower part of air cleaner
housing
|
• |
Attach upper part of air cleaner housing to lower part of air
cleaner housing
|
|
4. |
Install air cleaner housing
• |
Insert air cleaner housing into rubber bearing
|
• |
Push air intake pipe onto air cleaner housing
|
• |
Attach air intake hose to throttle valve module
|
• |
Attach engine vent hose to timing case
|
• |
Connect hot film mass air flow meter wiring harness plug
|
|
|