Check and correct hydraulic fluid level - Tutela
CS-Speed oil (M20 MTA)
Important: Only
"Tutela CS-Speed oil" may be used. If there is a loss of hydraulic
fluid without repair, the cause must be determined.
Remove
Important: At full system
pressure (approx. 45 bar), the hydraulic fluid pressure must lie
above the "MIN" mark (3).
After repair work or pressure release with TECH 2, with
pressureless system (0 bar), the hydraulic fluid must be topped up
to just below the lower edge of the fill connection on the
reservoir (2).
|
2. |
Check and correct hydraulic fluid level
• |
Open cover of hydraulic fluid reservoir (1) and top up
hydraulic fluid
Note: If necessary.
|
• |
Attach cover of hydraulic fluid reservoir
|
|
|
|
Install
3. |
Install battery support
|
4. |
Program volatile memories
|
|