Replacing the Servo Motor for Central Locking -
Front Door
1. |
Detach door inner panelling
|
2. |
Partially detach water vapour barrier (1)
• |
Detach bearing bracket (2)
|
|
|
|
3. |
Remove door lock
Note: The servo motor
and door lock form a single component
|
|
|
Install
5. |
Attach water vapour barrier
• |
Wet the edge of the water vapour barrier with spray adhesive
and bond
|
• |
Install bearing bracket
|
|
6. |
Install door inner panelling
|
|