vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Pressure Loss, Check > < Measuring oil consumption

Compression, Check

Engine at operating temperature (oil temperature >= 80 °C).

  Remove

For X 25 XE, X 30 XE: Remove oil filler opening port. Detach wiring harness plug from DIS ignition module.

For X 25 XE and X 30 XE: Pull fuel pump relay (1) out of socket.

Remove all spark plugs – see operation "Spark Plugs, Remove and Install (X 25 XE, X 30 XE)" or "Spark Plugs, Remove and Install (Y 26 SE, Y 32 SE)".

Object Number: 2387547  Size: DEFAULT

Note:   For Y 26 SE and Y 32 SE: Open throttle valve using TECH 2 – use "Compression test" (TECH 2) program.

  Inspect

Use compression recorder with rubber cone and measuring range up to 1750 kPa (17.5 bar) gauge pressure. Actuate starter for approx. 4 seconds with throttle valve fully open – minimum engine speed 300 rpm. The pressure difference between individual cylinders should not exceed 100 kPa (1 bar).

  Install

Install all spark plugs – see operation "Spark Plugs, Remove and Install (X 25 XE, X 30 XE)" or "Spark Plugs, Remove and Install (Y 26 SE, Y 32 SE)".

For X 25 XE, X 30 XE: Note ignition cable routing. Connect port of oil filler opening. Attach wiring harness plug to DIS ignition module. Insert fuel pump relay into socket.


Related Literature Units
-
-
-
-

Pressure Loss, Check > < Measuring oil consumption