· Charge
pressure lower than 480 hPa (0.48 bar) (voltage lower than 710 mV)
(interruption or short circuit
to ground)
· Condition
must be fulfilled for at least 3.5 s
Replacement values:
· Charge
pressure: 1000 hPa (1.0 bar)
· Atmospheric
pressure: 850 hPa (0.85 bar)
Effects:
· Maximum
output is reduced.
· The
injection amount is reduced to 21 mg / stroke.
|