64
|
FUEL
QUANTITY CONTROL OUT OF RANGE
|
20,
21, 36, 37, 38, 39, 40
|
· Engine
speed higher than 773 rpm (MT vehicles), 751 rpm (AT vehicles)
· Actual
voltage of injection quantity sensor greater than 1.3 V
· Voltage
of pump actuator: nominal voltage minus actual value greater than 670 mV
· Conditions
must be fulfilled for at least 0.52 s
Effects:
· The
engine is switched off.
|