vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

F6: ADJUSTMENTS - No. 02 MAX.FUEL Q.OFF > < F5: ACTUATOR TEST - No. 07 CHECK LIGHT

Digital Diesel Electronics DDE 2.1 System Modification F 6: ADJUSTMENTS

 

IDLE SPEED

 

Conditions for Checking

Nominal Value

Affected Terminals:

Possible Trouble Codes:

 

Engine running at idle speed, operating temperature

 

Vehicle stationary

Air conditioning OFF

 

Press key F 6 in the main menu, select the desired test using the arrow keys and confirm with YES. Follow the instructions in the TECH 1 display.

 

Note:

In this mode, it is possible to increase / decrease the engine idle speed in the range from approx. 614 to 842 rpm (AT) or approx. 614 to 865 rpm (MT) using the arrow keys.

In this adjustment mode, TECH 1 specifies the previously adjusted engine speed to the control unit and the control unit regulates the engine to this speed.

This mode should be used if the engine idles irregularly, jerks or runs too high at idle speed.

 

-

 

 

 

F6: ADJUSTMENTS - No. 02 MAX.FUEL Q.OFF > < F5: ACTUATOR TEST - No. 07 CHECK LIGHT