· See
Table F5: ACTUATOR TEST, test step 10
· Engine
running at idle speed
· Plug
of exhaust gas recirculation valve Y 18 connected
· Measure
voltage at exhaust gas recirculation valve Y 18 / Ter. C to
Ter. B (using adapter cable)
|
0.7 to 0.9 V
|
· Interruption
or short circuit from
- exhaust
gas recirculation valve Y 18 / Ter. C (signal lead) to control
unit K 61 / Ter. 50
- control
unit K 61 / Ter. 30 to exhaust gas recirculation valve
Y 18 / Ter. B
- control
unit K 61 / Ter. 12 to exhaust gas reeirculation valve
Y 18 / Ter. D
|
· Using
multimeter, measure voltage between Ter. D and Ter. B in plug of
exhaust gas recirculation valve Y 18 (using adapter cable)
|
greater than 4.9 V
|
· Lead
interruption or short circuit to ground from
- control
unit K 61 / Ter. 30 to plug of exhaust gas recirculation valve
Y 18 / Ter. B
- control
unit K 61 / Ter. 12 to plug of exhaust gas recirculation valve
Y 18 / Ter. D
|
Nominal values are attained
|
|
· Mechanical
part of exhaust gas recirculation valve defective
· Electrical
part of exhaust gas recirculation valve defective
· Control
unit K 61 defective
|