· Final
stage diagnosis in control unit (short circuit to voltage)
Replacement value:
The control unit retards the
firing angle by up to
X 25 XE:
12° CA
X 30 XE:
6° CA
for safety reasons.
The value varies depending on
the engine speed.
Effect: