vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

F2: TROUBLE CODES - Trouble Code 94 HALL SENSOR VOLTAGE HIGH > < Terminal Assignment, Control Unit Plug (X 25 XE / X 30 XE) Omega-B MY '94 1/2

Motronic M 2.8.1    F2: TROUBLE CODE TABLE

 

 

Trouble Code

Information Sensor

Cause of Fault

Remedy in

F0: DATA LIST

No.

Trouble Code Storage when...

93

 

HALL SENSOR

VOLTAGE LOW

 

 

10

 

·   Recognition of more than one phase information during one operating cycle with correct reference marks

     (short circuit to ground)

·   Condition must be fulfilled more than 50 times

 

Replacement values:

·   If the engine load signal is greater than 2.6 ms (X 25 XE) or 1.8 ms (X 30 XE) and the coolant temperature is higher than 45 °C / 13 °F, the control unit retards the firing angle by up to 12 °CA for reasons of safety.

     The value varies depending on the engine speed.

 

 

 


Related Literature Units
-F0: DATA LIST - Test Step 10 HALL SENSOR

F2: TROUBLE CODES - Trouble Code 94 HALL SENSOR VOLTAGE HIGH > < Terminal Assignment, Control Unit Plug (X 25 XE / X 30 XE) Omega-B MY '94 1/2