· The
control unit did not recognize 58 teeth pulses between the synchronizing
marks on the crankshaft pulley
· The
time in which a tooth gap was recognized is not plausible
· If
trouble code 19 and an engine speed higher than 8000 rpm are recognized,
trouble code 92 (camshaft fault) is also stored
(short circuit to ground or
circuit interruption)
(short circuit of signal
lead to oscillator lead)
(loose contact in signal
leads)
· Conditions
must be fulfilled for at least 3.5 s
Replacement values:
· The
crankshaft position, engine speed and firing angle output are calculated from
the camshaft signal
· The
engine speed is limited to 4512 rpm
Effects:
· If
trouble code 92 is stored along with trouble code 19, injection and ignition
are blocked
Note:
Emergency operation remains active until next ignition Off
|