Secondary Air Switchover Valve, Remove and Install
(X 20 XEV, X 25 XE and X 30 XE)
Remove
Disconnect wiring harness plug (2) from secondary air switchover
valve. Disconnect secondary air switchover valve from bracket. Mark
vacuum hoses and disconnect from secondary air switchover
valve.
Install
Connect vacuum hoses – note marks made beforehand!
|
1
|
Brake servo connection
|
3
|
Secondary air cutoff valve connection
|
Attach secondary air switchover valve to bracket – 4 Nm /
3 lbf. ft.
|
Connect wiring harness plug to secondary air switchover
valve.
|
|
|
|