vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

ATWS, F0: DATA LIST - Test Step 18 U/S ALARM > < ATWS, F0: DATA LIST - Test Step 16 ARM/DISARM CIR.

ATWS, F0:DATA LIST

 

 

 

 

 

 

     from:    S86/Ter. 2

     to:         S86/Ter. 3

(note stamp on switch S86)

 

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

 

Terminal

17

U/S SWITCH

 

Interior monitor button not pressed

 

 

Interior monitor button pressed

 

 

Note:

 

In the above test, the TECH 1 parameter IMMOBILISATION changes to

ACTIVE 0V.

Despite this, the engine can be started.

This is not a system malfunction.

 

INACTIVE 12V

 

 

ACTIVE    0V

(LED in button flashes)

 

28

29

Notes on Trouble-shooting:

Nominal Value:

Cause of Fault:

(If nominal value is not attained)

 

·   Remove interior monitor button S86

INACTIVE   12V

 

·   Instrument panel wiring harness, short circuit to ground

     from:    K94/Ter. 29

     to:         S86/Ter. 2

 

 

·   Control unit K94 defective

 

 

·   Connect bushing S86 in instrument panel

ACTIVE      0V

 

·   Instrument panel wiring harness, interruption

     from:    K94/Ter. 29

     to:         S86/Ter. 2

 

 

·   Instrument panel wiring harness, interruption

     from:    S86/Ter. 3

     to:         ground

 

 

·   Control unit K94 defective

 

 

If nominal values are attained:

 

·   Switch S86 defective

 

 

 

 

 

ATWS, F0: DATA LIST - Test Step 18 U/S ALARM > < ATWS, F0: DATA LIST - Test Step 16 ARM/DISARM CIR.