ATWS, F0:DATA LIST

 

 

 

 

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

19

HORN RELAY

 

Ignition OFF

Driver's door not completely closed, see note.

Turn key 60° to the right in driver's door

(arm anti-theft warning system)

Wait at least 10 s

Open driver's door

Country code "D"

 

 

alternately

INACTIVE 12V

and

ACTIVE    0V

ALARM is triggered (turn signal lamps and horn active)

 

25

-

 

 

Important:

 

The following alarms deviate from country code "D":

Country

code "CH":    only horn

                      (continuous note),

country

code "NL":    horn (continuous note) and turn signal units,

country

code "GB":    only horn

 

 

 

 

 

 

 

Turn key 30° to the left in driver's door

(disarm anti-theft warning system)

 

 

Note:

 

For this check, the TECH 1 lead should be routed through the gap between the B pillar and the driver's door left ajar. The driver's door contact switch must be actuated.

 

 

When alarm is triggered, the immobiliser is activated.

 

 

The immobiliser can only be deactivated by the infrared transmitter.

 

 

 

 

Notes on Trouble-shooting:

Nominal Value:

Cause of Fault:

(If nominal value is not attained)

 

 

 

·   Control unit K94 defective

 

 

 

 