No.
|
TECH 1 Display
|
Conditions for Checking
|
Nominal Value
|
Trouble Codes
|
Terminal
|
06 |
CO-DR. UNLOCK SW
|
Ignition
OFF
All
doors closed
|
|
-
|
12
|
|
|
Turn
key 30° to the right in co-driver's door (unlock central locking)
|
CLOSED 0V
|
|
|
|
|
Turn
key 30° to the left in co-driver's door (lock central locking)
|
OPEN 12V
|
|
|
|
|
Turn
key 30° to the right in co-driver's door (unlock central locking)
|
|
|
|
Notes
on Trouble-shooting: |
Nominal
Value:
|
Cause
of Fault:
(If
nominal value is not attained)
|
· Release and disconnect wiring harness plug,
body and co-driver's door X12 |
OPEN 12V
|
· Body wiring harness, short circuit to ground
from: K37/Ter. 12
to: X12/Ter. 1
· Control unit K37 defective
|
· Connect wiring harness plug X12/Ter. 1 in
body wiring harness to ground |
CLOSED 0V
|
· Body wiring harness, interruption
from: K37/Ter. 12
to: X12/Ter. 1
· Control unit K37 defective
|
· Connect wiring harness plug, body and
co-driver's door X12 again |
|
|
· Release and disconnect wiring harness plug
S42 |
|
|
· Connect wiring harness plug S42/Ter. 3 in
front door wiring harness to ground |
CLOSED 0V
|
· Front door wiring harness, interruption
from: X12/Ter. 1
to: S42/Ter. 3
|
If nominal values are attained: |
|
· Switch S42 defective
|
|
|
|
|
|
|
|